Overview
Product Overview
The AELAB SYD-5208 is a Rapid Low Temperature Closed Cup Flash Point Tester designed for rapid equilibrium closed cup flash point determination. It is designed and made according to GB/T 5208-2008 Determination of Flash Point – Rapid Equilibrium Closed Cup Method and also corresponds with ISO 1523 and ISO 3679.
The instrument is particularly suitable for colored paints, oil paints, adhesives, solvents and petroleum products with closed cup flash points from -30℃ to +100℃. The catalog also specifies applications in oil, chemical, varnish, paint, railway, aviation, electricity, commercial inspection and scientific research fields.
The SYD-5208 requires only 2ml of liquid sample or 4ml of solid or semi-solid sample for rapid equilibrium testing. Its refrigeration system combines semiconductor refrigeration with compressor refrigeration circulating water used to cool the semiconductor refrigeration devices. The integrated system does not require external cooling water.
A color touch screen and single-chip control system provide instrument operation and control through the display. The instrument automatically controls temperature and constant-temperature operation, automatically detects the flash point, and locks and prints the test result after testing.
Key Features
- Rapid Equilibrium Closed Cup Method: Designed according to GB/T 5208-2008 and corresponding with ISO 1523 and ISO 3679.
- Low-Temperature Flash Point Range: Measures closed cup flash points from -30℃ to +100℃.
- Small Sample Requirement: Uses 2ml for liquid samples and 4ml for solid or semi-solid samples.
- Integrated Refrigeration System: Combines semiconductor refrigeration with compressor refrigeration circulating water for cooling the semiconductor refrigeration devices.
- No External Cooling Water: The integrated cooling design does not require an external cooling-water supply.
- Color Touch Screen: Instrument operation and control are completed through the color touch-screen display.
- Automatic Temperature Control: Automatically controls heating/cooling and constant-temperature operation during testing.
- Automatic Flash Point Detection: Automatically detects the flash point and locks the test result.
- Result Printing: Test results can be printed after the test.
- Electric Ignition: The specified igniting device is an electric igniting gun.
Applications
- Colored Paints: Rapid equilibrium closed cup flash point determination.
- Oil Paints: Closed cup flash point testing within the specified -30℃ to +100℃ range.
- Adhesives: Flash point determination using the rapid equilibrium closed cup method.
- Solvents: Low-temperature closed cup flash point testing.
- Petroleum Products: Rapid determination of closed cup flash point within the specified range.
- Industry and Testing Fields: The catalog lists oil, chemical, varnish, paint, railway, aviation, electricity, commercial inspection and scientific research institutions.
Test Methods and Standards
- GB/T 5208-2008: Determination of Flash Point – Rapid Equilibrium Closed Cup Method
- ISO 1523: Referenced by the catalog as a corresponding standard
- ISO 3679: Referenced by the catalog as a corresponding standard
Product Information
- Brand: AELAB
- Manufacturer: AELAB GUANGZHOU CO., LTD.
- Product Type: Rapid Low Temperature Closed Cup Flash Point Tester
- Model: SYD-5208
- Test Method: Rapid equilibrium closed cup method
- Flash Point Measuring Range: -30℃~+100℃
- Liquid Sample Amount: 2ml
- Solid/Semi-Solid Sample Amount: 4ml
FAQ
What is the SYD-5208 used for?
It is used for rapid equilibrium closed cup flash point determination of colored paints, oil paints, adhesives, solvents and petroleum products.
Which standards does the SYD-5208 correspond with?
The instrument is designed according to GB/T 5208-2008 and also corresponds with ISO 1523 and ISO 3679.
What is the flash point measuring range?
The specified flash point measuring range is -30℃~+100℃.
How much sample is required?
The catalog specifies 2ml for a liquid sample and 4ml for a solid or semi-solid sample.
Does the SYD-5208 require external cooling water?
No. Its integrated refrigeration design does not require external cooling water.
What ignition system does the instrument use?
The specified igniting device is an electric igniting gun, with gas, LPG or other civilian fuels listed as the igniting source.
Does the SYD-5208 detect the flash point automatically?
Yes. It automatically controls temperature, detects the flash point, locks the result and prints the test result after testing.
What is the catalog-specified temperature resolution?
The catalog specifies the temperature resolution as ±0.1℃.
Who manufactures the SYD-5208?
The SYD-5208 is supplied under the AELAB brand by AELAB GUANGZHOU CO., LTD.