Laser Dust Particle Counter AE-310 / AE-550 / AE-5100

Laser Dust Particle Counter AE-310 / AE-550 / AE-5100

Model :AE-310~ AE-550~AE-5100

  • Models & Sampling Flow: AE-310 28.3 LPM; AE-550 50 LPM; AE-5100 100 LPM
  • Particle Size Channels: AE-310: 0.3–10.0 μm; AE-550/AE-5100: 0.5–25.0 μm, six channels per model
  • Flow Control: Built-in high-precision mass flow meter with ±3% flow accuracy
  • Compliance & Reports: FDA 21 CFR Part 11, GB/T 29024.4-2017 / ISO 21501-4:2007; generates GB/T 25915.1-2021 / ISO 14644-1:2005 reports
  • Data & Control: 10-inch capacitive touch screen, audit trail, 3-level access control, USB export and 10 million normal data records

Overview

Product Overview

The AELAB AE-310, AE-550 and AE-5100 are Laser Dust Particle Counters designed for airborne particle measurement with three sampling-flow configurations: 28.3 LPM, 50 LPM and 100 LPM.

The instruments use a stainless steel shell resistant to disinfectants commonly used in clean rooms and incorporate a built-in high-precision mass flow meter with specified flow accuracy of ±3%. A 10-inch capacitive touch screen provides access to sampling settings, data management, alarms and report functions.

The three models share the same overall dimensions and core data-management functions but differ in sampling flow rate, weight and particle-size channel configuration. AE-310 measures six channels from 0.3 μm to 10.0 μm, while AE-550 and AE-5100 measure six channels from 0.5 μm to 25.0 μm.

The system supports multi-level authority management with audit trail functionality, room-based data organization, USB output, real-time particle concentration curves and large-capacity storage. The catalog specifies compliance with FDA 21 CFR Part 11 and GB/T 29024.4-2017 / ISO 21501-4:2007 and states that reports compliant with GB/T 25915.1-2021 / ISO 14644-1:2005 can be generated directly.

Key Features

  • Three Sampling Flow Options: AE-310 provides 28.3 LPM, AE-550 provides 50 LPM and AE-5100 provides 100 LPM.
  • High-Precision Flow Measurement: Built-in mass flow meter provides specified flow accuracy of ±3%.
  • 10-Inch Capacitive Touch Screen: Large touch interface with a clear command layout for instrument operation.
  • Stainless Steel Housing: The shell is resistant to disinfectants commonly used in clean rooms.
  • Real-Time Concentration Curve: Displays changing environmental particle conditions during sampling.
  • Flexible Sampling Settings: Provides an adjustable sampling interval from 1 second to 999,999 seconds and quick editing of sampling parameters.
  • Room-Based Sampling Plans: Users can create personalized sampling plans for individual rooms.
  • Large Data Capacity: Supports more than 10 million sampling data records, up to 50,000 rooms and 500,000 points.
  • Statistical Data Processing: Automatically generates point averages, total averages and statistical data.
  • Audit Trail: Multi-level authority management is combined with audit trail functionality.
  • Three-Level Access Control: Administrator, Technician and Operator access levels are specified.
  • USB Export: Supports export of PDF reports and data through a USB flash drive.
  • Built-In Thermal Printer: All three models specify a built-in thermal printer; a Bluetooth needle printer is optional.
  • HEPA-Filtered Exhaust: Built-in HEPA filter with >99.997% filtration at 0.3 μm.
  • Alarm Functions: Flow alarm, battery alarm and count alarm are provided.

Applications

  • Cleanroom Particle Monitoring: Airborne particle measurement in environments where cleanroom-compatible construction and particle monitoring are required.
  • Room-Based Particle Sampling: Customizable sampling plans and room-organized data support measurements across multiple rooms and sampling points.
  • Environmental Particle Condition Monitoring: Real-time concentration curves support observation of environmental particle conditions during sampling.
  • Standards-Based Particle Measurement: Testing using equipment specified as compliant with GB/T 29024.4-2017 / ISO 21501-4:2007.
  • Cleanroom Report Generation: Direct generation of reports compliant with GB/T 25915.1-2021 / ISO 14644-1:2005.

Model Comparison

Model Sampling Flow Rate Particle Size Channels Weight
AE-310 28.3 LPM 0.3, 0.5, 1.0, 2.0, 5.0, 10.0 μm 6 kg (including battery)
AE-550 50 LPM 0.5, 1.0, 2.0, 5.0, 10.0, 25.0 μm 6.5 kg (including battery)
AE-5100 100 LPM 0.5, 1.0, 2.0, 5.0, 10.0, 25.0 μm 7 kg (including battery)

Compliance and Data Integrity

  • FDA 21 CFR Part 11: The catalog states that the particle counter is compliant with FDA 21 CFR Part 11.
  • GB/T 29024.4-2017 / ISO 21501-4:2007: The catalog specifies compliance with these particle-counter standards.
  • GB/T 25915.1-2021 / ISO 14644-1:2005: The system can directly generate reports compliant with these standards.
  • Audit Trail: Supports traceability of instrument operation and data-management activities.
  • User Access Control: Three access levels are specified: Administrator, Technician and Operator.

Data Management and Reporting

  • Normal Data Records: 10 million
  • Statistical Data Records: 100,000
  • Room Capacity: Up to 50,000 rooms
  • Sampling Point Capacity: Up to 500,000 points
  • Counting Units: Data is organized by room with free switching of counting units.
  • Automatic Calculations: Generates point average, total average and statistical data.
  • USB Output: Supports direct export of PDF reports and data through USB flash drive.

Product Information

  • Brand: AELAB
  • Manufacturer: AELAB GUANGZHOU CO., LTD.
  • Product Type: Laser Dust Particle Counter
  • Models: AE-310, AE-550 and AE-5100
  • Sampling Flow Rates: 28.3 LPM, 50 LPM and 100 LPM
  • Flow Accuracy: ±3%
  • Display: 10-inch capacitive touch screen
  • Language: Chinese / English

FAQ

Which models are included on this Laser Dust Particle Counter page?

The supplied catalog specifies three models: AE-310, AE-550 and AE-5100.

What sampling flow rates are available?

AE-310 provides 28.3 LPM, AE-550 provides 50 LPM and AE-5100 provides 100 LPM.

What particle size channels does each model measure?

AE-310 measures 0.3, 0.5, 1.0, 2.0, 5.0 and 10.0 μm. AE-550 and AE-5100 measure 0.5, 1.0, 2.0, 5.0, 10.0 and 25.0 μm.

What is the maximum allowed particle concentration?

All three models specify a maximum allowed concentration of 35,000 particles/L for dust particles ≥0.5 μm.

What sample-air limitation is specified?

The catalog states that sample air must not contain acidic or corrosive gases.

What standards and data-integrity requirements are supported?

The catalog states compliance with FDA 21 CFR Part 11 and GB/T 29024.4-2017 / ISO 21501-4:2007. It also states that the instrument can directly generate reports compliant with GB/T 25915.1-2021 / ISO 14644-1:2005.

How much data can the system store?

Each model specifies storage for 10 million normal data records and 100,000 statistical data records. The catalog also states that the system can store 50,000 rooms and 500,000 points.

What user access levels are available?

The three specified access levels are Administrator, Technician and Operator. Multi-level authority management is combined with an audit trail function.

What printer is provided?

A built-in thermal printer is specified for all three models. A Bluetooth needle printer is optional.

What exhaust filtration is provided?

All three models use a built-in HEPA exhaust filter with specified filtration efficiency greater than 99.997% at 0.3 μm.

Specifications

Parameter AE-310 Specifications AE-550 Specifications AE-5100 Specifications
Dimensions 279 × 202 × 295 mm 279 × 202 × 295 mm 279 × 202 × 295 mm
Weight 6 kg (including battery) 6.5 kg (including battery) 7 kg (including battery)
Language Chinese / English Chinese / English Chinese / English
Power Supply DC 16.8 V (rechargeable lithium battery) DC 16.8 V (rechargeable lithium battery) DC 16.8 V (rechargeable lithium battery)
Particle Size Channels 0.3, 0.5, 1.0, 2.0, 5.0, 10.0 μm 0.5, 1.0, 2.0, 5.0, 10.0, 25.0 μm 0.5, 1.0, 2.0, 5.0, 10.0, 25.0 μm
Sampling Interval 1 second – 999,999 seconds (adjustable) 1 second – 999,999 seconds (adjustable) 1 second – 999,999 seconds (adjustable)
Sampling Flow Rate 28.3 LPM 50 LPM 100 LPM
Maximum Allowed Concentration 35,000 particles/L (for dust particles ≥0.5 μm) 35,000 particles/L (for dust particles ≥0.5 μm) 35,000 particles/L (for dust particles ≥0.5 μm)
Sample Concentration Limitation Sample air must not contain acidic or corrosive gases Sample air must not contain acidic or corrosive gases Sample air must not contain acidic or corrosive gases
Alarms Flow alarm, battery alarm, count alarm Flow alarm, battery alarm, count alarm Flow alarm, battery alarm, count alarm
Exhaust Built-in HEPA filter (>99.997% @ 0.3 μm) Built-in HEPA filter (>99.997% @ 0.3 μm) Built-in HEPA filter (>99.997% @ 0.3 μm)
Printer Built-in thermal printer, optional Bluetooth needle printer Built-in thermal printer, optional Bluetooth needle printer Built-in thermal printer, optional Bluetooth needle printer
Data Storage 10 million normal data records, 100,000 statistical data records 10 million normal data records, 100,000 statistical data records 10 million normal data records, 100,000 statistical data records
Data Security 3-level access control: Administrator, Technician, Operator 3-level access control: Administrator, Technician, Operator 3-level access control: Administrator, Technician, Operator

Request Quote: Laser Dust Particle Counter AE-310 / AE-550 / AE-5100

Request Quote: Laser Dust Particle Counter AE-310 / AE-550 / AE-5100