  • Test Method: Pulsed ultraviolet fluorescence method according to SH/T 0689
  • Sample States: Liquid, gas and solid
  • Liquid Measurement Range: 0.1mg/L~10000mg/L with 0.05mg/L lower detection limit
  • Test Time: About 2 minutes per sample
  • Temperature Range: Room temperature~1200℃ with catalog-specified 0.5%±1℃ temperature control accuracy

Overview

Product Overview

The AELAB SYD-0689 is an Ultraviolet Fluorescence Sulfur-in-Oil Analyzer for determining total sulfur content using a pulsed ultraviolet fluorescence method combined with computer control technology.

The instrument is made according to SH/T 0689 Light Hydrocarbons, Engine Fuels and Other Oils for the Determination of Total Sulfur Content (Ultraviolet Fluorescence Method). It is suitable for low-sulfur testing of gasoline and diesel, including the National V standards referenced by the catalog, as well as total sulfur determination in liquid, gas and solid samples.

For liquid samples, the specified measurement range is 0.1mg/L~10000mg/L with a lower detection limit of 0.05mg/L. The test time for each sample is approximately 2 minutes.

The SYD-0689 uses a Windows-based desktop computer platform. Data collection, processing, storage and printing are completed through computer control. The integrated desktop system combines the host, computer system, temperature and flow controller, and sampler.

Key Features

  • Windows Computer Platform: Parameter settings and tests are completed through direct human-machine interaction on a desktop computer.
  • Automatic Data Processing: Computer control automatically completes data collection, processing, storage and printing.
  • Wide Linear Range and Anti-Interference: The catalog specifies a wide linear test range and strong anti-interference capability.
  • Fluorescence Components: Uses an imported fluorescence excitation source, membrane desiccant and filter.
  • Temperature Control: Provides rapid and stable heating with catalog-specified temperature control accuracy of 0.5%±1℃ across the full temperature-control range.
  • Multiple Sample States: Measures sulfur content in liquid, gas and solid samples.
  • Integrated Desktop Structure: The host, computer system, temperature and flow controller, and sampler form an assembled integrated system.
  • Fast Testing: The catalog specifies an instrument test time of about 2 minutes for each sample.

Applications

  • Gasoline and Diesel: Low-sulfur content determination, including the National V standards referenced by the catalog.
  • Liquid Samples: Total sulfur determination by pulsed ultraviolet fluorescence.
  • Gas Samples: Total sulfur content testing within the instrument’s supported sample-state scope.
  • Solid Samples: Total sulfur content determination for applicable solid samples.
  • Petroleum and Chemical Industry: The catalog identifies these as application fields for sulfur analysis.
  • Electric Power and Coal: Sulfur-content analysis in the catalog-specified application fields.
  • Food and Environmental Protection: The catalog also identifies food and environmental protection as supported application fields.

Test Method and Standard

  • SH/T 0689: Light Hydrocarbons, Engine Fuels and Other Oils for the Determination of Total Sulfur Content (Ultraviolet Fluorescence Method)
  • Measurement Principle: Pulsed ultraviolet fluorescence method combined with computer control technology

Product Information

  • Brand: AELAB
  • Manufacturer: AELAB GUANGZHOU CO., LTD.
  • Product Type: Ultraviolet Fluorescence Sulfur-in-Oil Analyzer
  • Model: SYD-0689
  • Measured Parameter: Total sulfur content
  • Test Method: Pulsed ultraviolet fluorescence
  • Sample States: Liquid, gas and solid
  • Liquid Measurement Range: 0.1mg/L~10000mg/L
  • Lower Detection Limit: 0.05mg/L
  • Default Unit: mg/L; changes to mg/kg when sample density is entered

FAQ

What is the SYD-0689 used for?

It is used to determine total sulfur content by the pulsed ultraviolet fluorescence method.

Which standard does the SYD-0689 follow?

The catalog specifies SH/T 0689 for determination of total sulfur content in light hydrocarbons, engine fuels and other oils by ultraviolet fluorescence.

Which sample states can be tested?

The SYD-0689 supports liquid, gas and solid samples.

What is the measurement range for liquid samples?

The specified liquid measurement range is 0.1mg/L~10000mg/L.

What is the lower detection limit?

The specified lower detection limit is 0.05mg/L.

How long does one test take?

The catalog states that the machine test time for each sample is about 2 minutes.

What is the temperature range?

The specified temperature range is from room temperature to 1200℃.

What result units are available?

The default unit is mg/L. If sample density is entered, the unit changes to mg/kg.

Who manufactures the SYD-0689?

The SYD-0689 is supplied under the AELAB brand by AELAB GUANGZHOU CO., LTD.

Specifications

Parameter Specification
Test method Pulsed ultraviolet fluorescence method
State of measurable samples Liquid, gas, solid
Measurement range 0.1mg/L~10000mg/L (Liquid)
Lower detection limit 0.05mg/L
Repeatability error X≤0.5mg/L;±0.1mg/L 0.5mg/L<X≤1.0mg/L; Cv≤10% 1.0mg/L<X≤5.0mg/L; Cv≤5% X>5.0mg/L; Cv≤2.5%
Temp. range room temperature~1200℃;
Temp. control accuracy 0.5%±1℃
High voltage range DC 0V~900V, according to the concentration of the measured sample, set the required value through the operating system
Power supply AC 220V±22V,50Hz±1Hz
Total power consumption ≤3kW
Dimension 660mm×500mm×400mm (Computer is not included)
Net weight 40kg (Computer is not included)
Default Unit mg/L, if input the density, the unit is changed mg/kg

Request Quote: Ultraviolet Fluorescence Sulfur-in-Oil Analyzer SYD-0689

Request Quote: Ultraviolet Fluorescence Sulfur-in-Oil Analyzer SYD-0689