| Model |
eQ1620 |
eQ162Cp |
eQ164CP |
| Sample volume |
16*0.2 ml single tube or 8-strip transparent tube (except for white opaque tube), you can mark the tube with markers on the cover of the tube. |
| Applicable reagents |
The system is an open platform, suitable for various real-time PCR reagents, including fast extraction reagents, non-extraction reagents or direct amplification reagents and other low-concentration PCR reagents. |
| Reaction volume |
5-100ul |
| Dynamic range |
1-10° Copies |
| Color wavelength |
400-700nm |
| Optical sensor |
PMT |
PD |
PD |
| Dyes and probes |
CH1:FAM、SYBR Greenl ;CH2:HEX、JOE、MC、ROX. |
CH1: FAM、SYBR Green l ;
CH2:HEX、JOE、VIC、TAMRA;
CH3:ROX、CALRED:
CH4:CY5、QUASAR |
| Detection technology |
Scientific grade, suitable for micro-reaction system. |
Double PD detection, practical grade, suitable for conventional reaction system. |
Four PD detection,independent excitation fluorescence detection, suitable for multiple PCR. |
| Unique design of DFD photoelectric module |
DFD two-dimensional precision photoelectric module, independent 4-color channel, micro-gap direct photometry, high signal-to-noise ratio, Strong ability to resist environmental light interference, The crosstalk between fluorescent channels is very low to avoid misjudgment of amplification results |
| Sensitivity |
1 Copy |
| Rn |
>0.998 |
| CV |
≤0.6% |
| Block setting range |
10-99.9°C |
| Temperature control mode |
Tube mode.Real temperature of simulated reagent. |
| Refrigeration technology |
Peltier |
| ETSC block temperature equalization technology |
The know-how of block edge temperature self-compensation design (ETSC) not only reduces the weight of the block, but also achieves excellent temperature uniformity, which effectively shortens the time of PCR experiment. |
| Precision of temperature control |
≤0.1°C |
| Display resolution |
0.1°C |
| Temperature accuracy |
≤0.2°C |
| Temperature uniformity |
≤±0.2°C |
| Max, ramping rate |
≥4°C/s |
| Avg, ramping rate |
≥2.5°C/s(50-90°C) |
| Hot lid |
30-105°C, Default 105°C. |
| Operating mode |
Operate through PC (provided by customer). one PC can be used to control multiple PcR machines to form N * 16 PCR array to run N PCR experiments simultaneously, which is flexible and changeable. |
| PC operating system |
Windows7/10 |
| Com.interface |
RS232./USB |
| Software functions |
It has functions of system settings (password permission), experimental parameter settings, sample information input, operation management, data export EXCEL, general view of PCR program, real-time amplification curve display, channel crosstalk correction, criterion setting, automatic report, curve capture, etc. |
| Analytical functions |
Standard curve,Relative Quantitative curve and melting Curve(HRM) |
| Reports |
The human/animal experiment report templates are preset in the system, and the report template is also customized. Results Judgment, fluorescence analysis curve, report printing and other functions. |
| Specialized biodegradation function |
The built-in ultraviolet lamp (UV) can effectively degrade the aerosol contamination on the block and thermal hot lid, and the irradiation intensity is as high as 7OuW/cm2 |
| Operating indicator |
Power on, in operation, successful communication, ultraviolet degradation (UV),. fault alarm. hot lid open alarm. |
| operating ambient |
Ambient temperature:10-30 °C, relative humidity: 20-85% RH, elevation not higher than 2000 m.storage temperature:-20-60°C |
| Input power |
100-240V~300VA |
| Dimensions(LxWxH) |
324x212x122mm(A4 paper size) |
| Net weight |
5.8Kg |