Melting Point Devices DMP Series

Melting Point Devices DMP Series

Model :AE-MPD-100~AE-MPD200~AE-MPD300

The Melting Point Devices DMP Series provides reliable and accurate results for determining the melting points of a wide variety of substances. The entry-level DMP100 model supports a temperature range from ambient to 300°C and features a 0.1°C resolution display for precise readings. It can analyze up to three samples and offers adjustable ramp rates to suit your testing needs. The DMP200 model upgrades this with a faster ramp rate, improved light path for clearer viewing, and a more efficient control system for faster, accurate melting point readings. The premium DMP300 includes all the features of the DMP200, plus a cooling fan for faster cooling, double displays for ease of use, and a hand-held “READ” push button to simplify data recording. Additionally, the DMP300 offers data recording capabilities and is designed for easy calibration.

Overview

The Melting Point Devices DMP Series offers a comprehensive range of precision equipment for determining the melting points of various substances. The DMP100, DMP200, and DMP300 models are designed with advanced features and various options to meet the diverse needs of laboratories. The DMP100, the entry-level model, offers reliable performance with a temperature range from ambient to 300°C and a display resolution of 0.1°C. It can accommodate up to three samples at once and offers both fast and slow ramp rates for precise control of the heating process. The DMP200 builds upon this foundation with enhanced functionality, allowing for faster temperature ramping at 20°C/min, a more efficient light path for clearer viewing, and improved control of the fast stage temperature to reduce measurement time. The DMP300 takes this a step further with an internal cooling fan that enables a cooling rate of 25°C/min, double displays for both inside and outside views, and a hand-held “READ” push button for quicker data recording. Additionally, the MPD300 offers data storage for permanent recording and is fully capable of calibration, either chemically or with an external probe. Whether you’re working with smaller quantities or need to ensure quick cooling between tests, the DMP Series offers a versatile, cost-effective solution for precise melting point analysis.

DMP100 Features:

  • Temperature Range: Ambient to 300°C

  • Temperature Accuracy: ± 0.5°C

  • Display: Four-digit LED display

  • Display Resolution: 0.1°C

  • Number of Samples: Up to 3 samples simultaneously

  • Fast Ramp Rate: Fixed at 20°C/min

  • Slow Ramp Rate: Adjustable from 0.2°C/min to 10°C/min (in 0.1°C/min increments)

  • Calibration: Supports chemical calibration or external probe calibration

  • Design: Compact, suitable for basic laboratory needs


DMP200 Features:

  • Temperature Range: Ambient to 350°C

  • Temperature Accuracy: ± 0.5°C

  • Display: Four-digit LED display

  • Display Resolution: 0.1°C

  • Number of Samples: Up to 3 samples simultaneously

  • Fast Ramp Rate: Fixed at 20°C/min

  • Slow Ramp Rate: Adjustable from 0.2°C/min to 10°C/min (in 0.1°C/min increments)

  • Improved Light Path: Brighter and clearer view with no scattering or fuzzy vision

  • Fast Stage Temperature Control: Once fast stage temperature is reached, it is held without overshooting

  • Audible Reminder: A beep sounds when the fast stage temperature is reached, reminding users to proceed with the next step

  • “Read” Button: Simultaneously holds the melting point reading and heating process, allowing easy differentiation between two samples

  • Calibration: Supports chemical calibration or external probe calibration


DMP300 Features:

  • Temperature Range: Ambient to 400°C

  • Temperature Accuracy: ± 0.5°C

  • Display: Four-digit LED display

  • Display Resolution: 0.1°C

  • Number of Samples: Up to 3 samples simultaneously

  • Fast Ramp Rate: Fixed at 20°C/min

  • Slow Ramp Rate: Adjustable from 0.2°C/min to 10°C/min (in 0.1°C/min increments)

  • Cooling Rate: Internal fan with a cooling rate of 25°C/min

  • Cooling Process: Automatically starts after the analysis ends; fan turns off when temperature reaches 5°C below fast stage temperature

  • Dual Display: Inside and outside displays for ease of use, reducing the need to frequently switch between eyepiece and external display

  • Handheld “READ” Push Button: Allows users to quickly record data without having to search for the “READ” button on the main unit

  • Data Recording: Data is stored permanently until manually erased

  • “Read” Button: Simultaneously holds the melting point reading and heating process

  • Calibration: Supports chemical calibration or external probe calibration

Specifications

Technical specification:
Model DMP-100 DMP200 DMP300
Temperature range (ºC ) Ambient to 300 Ambient to 350 Ambient to 400
Temperature accuracy (ºC ) ± 0.5 ± 0.5 ± 0.5
Display Four digit LED Four digit LED Four digit LED
Display resolution (ºC ) 0.1 0.1 0.1
Readout and temperature hold Yes Yes Yes
Calibration Capability Yes Yes Yes
Number of samples 3 3 3
Fast Stage Ramp rate (ºC/min ) 20 fixed 20 fixed 20 fixed
Slow Ramp rates (ºC/min ) adjustable between 0.2 to 10 at 0.1 (ºC/min ) interval adjustable between 0.2 to 10 at 0.1 (ºC/min ) interval adjustable between 0.2 to 10 at 0.1 (ºC/min ) interval
Cooling rate (ºC/min ) - - 25
Inside Block Temperature View No No Yes
Hand held “READ” push button No No Yes
Data Recording No No Yes
Dimensions (w x d x h) No 160 x 220 x 170mm 160 x 220 x 170mm
Net weight 222*190*200 1.8 Kg 1.8 Kg
Electrical supply 2.5 Kg 120 or 230V, 50Hz, 75W 120 or 230V, 50Hz, 75W

Request Quote: Melting Point Devices DMP Series

Request Quote: Melting Point Devices DMP Series

(0/10)