ICP K8000 Inductively Coupled Plasma Emission Spectrometer

ICP K8000 Inductively Coupled Plasma Emission Spectrometer

Model :K8000

The AELAB ICP Inductively Coupled Plasma Emission Spectrometer model C-T is a desktop analytical instrument designed for simultaneous multi-element analysis in industrial and research laboratories. It measures over 70 metallic and non-metallic elements with high speed (approx.

Overview

Product Overview

The AELAB ICP Inductively Coupled Plasma Emission Spectrometer model C-T is a desktop analytical instrument designed for simultaneous multi-element analysis in industrial and research laboratories. It measures over 70 metallic and non-metallic elements with high speed (approx.

 

Instrument Feature

  • Multiple testing elements: More than 70 elements can be measured, including all metallic elements and the vast majority of non-metallic elements.
  • Simultaneous testing of multiple elements: Test all elements at once and produce results at once.
  • Fast analysis speed: Approximately 5 elements per minute, expandable up to 10 elements per minute.
  • Less chemical interference: There is basically no chemical interference, real-time background deduction, and the test results are more accurate.

 

Applications

  • Multi-element trace metal analysis
  • Simultaneous detection of metallic and non-metallic elements
  • Water quality monitoring
  • Soil and sediment analysis
  • Alloy composition testing
  • Pharmaceutical impurity profiling

FAQ

What elements can the C‑T ICP spectrometer measure?

It can measure more than 70 elements, including all metallic elements and the vast majority of non‑metallic elements.

What is the typical analysis speed?

The system analyzes approximately 5 elements per minute and is expandable up to 10 elements per minute.

How precise is the instrument?

For a 2 ppm mixed multi‑element solution, the relative standard deviation (RSD) is ≤ 1.5%. Stability over 2 hours has an RSD ≤ 2.0%.

Does the instrument offer automatic plasma ignition?

Yes, plasma ignition is fully automatic, and the plasma flame position can be adjusted in three dimensions via the computer.

What grating options are available and what wavelength ranges do they cover?

The instrument supports 4320 lines/mm (190‑460 nm), 3600 lines/mm (190‑500 nm), and 2400 lines/mm (190‑800 nm) gratings, with resolutions of ≤0.005 nm, ≤0.008 nm, and ≤0.015 nm respectively.

What type of optical system does the C‑T use?

It uses a Czerny‑Turner (C‑T) type optical system with a 1000 mm focal length and temperature stability of ±0.1°C.

Specifications

Technical Specifications

Category Details
Main Technical Parameters Observation System: Desktop, Plasma Vertical Observation System; Precision: 2ppm Mixed Multi-element Solution, RSD ≤ 1.5%; Stability: 2 Hours RSD ≤ 2.0%, Detection Limit Meets the A-level Requirements of the National Standard; Flame Adjustment: The Plasma Flame Can Be Adjusted in Three Dimensions (Front, Back, Up, Down, Left, Right, Controlled by Computer)
Injection System Torch Tube: Integrated Integrated Integrated Quartz Torch Tube; Atomizer: Efficient Concentric Nebulizer, Injection Speed 2ml/min; Atomization Chamber: Patented Extended Atomization Chamber, Optional with Swirl Atomization Chamber and Hydrofluoric Acid Resistant Atomization Chamber; Split Sampling System: For Real-time Observation of Sample Injection Status; Mass Flow Controller: Controls the Argon Flow Rate, Continuously Adjustable and Provides Real-time Numerical Feedback; Peristaltic Pump: Fully Automatic Five-channel Sixteen Roller Shaft, Continuously Adjustable Speed
RF Generator and Plasma Frequency: 27.12MHz, Frequency Stability ≤ 0.01%; Type: Solid State High-frequency RF Generator, Fast Water Cooling, Automatic Tuning; Power: 500W - 1600W, Continuously Adjustable, Adjustment Accuracy ≤ 1W, Power Stability ≤0.01%, Using 99.99% Argon Gas; Equipped with Reverse Power Protection Function for RF Power Supply; Plasma Ignition Is Fully Automatic Control
Optical System Optical Stability: Designed on the Same Platform as the Injection System; System Type: Cheney Turner Type (C-T Type), Focal Length 1000mm; Constant Temperature of the Optical System, Temperature Stability: ±0.1°C; Minimum Step Distance of Scanning Motor: ≤ 0.0004nm; Resolution Ratio (Mn257.610nm): ≤0.005nm (4320line Grating); ≤0.008nm (3600line Grating); ≤0.015nm (2400line Grating); Wavelength Range: 190 - 460nm (4320line Grating); 190 - 500nm (3600line Grating); 190 - 800nm (2400line Grating); The Best Testing Conditions for Different Elements Can Be Set