Model :T8001

Need Help with This Product?
The AELAB T8001 Graphite Furnace Atomic Absorption Spectrometer is a high-performance, computer-controlled instrument designed for reliable trace metal analysis. Operated via a USB 3.0 interface, it integrates the graphite furnace power supply and absorption host into a single housing, minimizing cable length and electromagnetic interference while enhancing graphite tube heating efficiency. The 150-position rotary automatic sampler ensures stable, accurate, and repeatable operation.
The T8001 employs an integrated total reflection achromatic optical system using concave mirrors to eliminate color-difference errors between focal points, improving optical efficiency. The streamlined sheet-metal enclosure provides superior thermal stability and durability. The graphite furnace features micro-resistance heating, precision temperature control (± 1 %), and real-time monitoring of carrier gas and temperature feedback.
The system utilizes a Czerny–Turner monochromator with 1800 lines/mm grating and 230 nm diffraction for element isolation. During operation, metal atoms are atomized within the graphite tube, and absorbance is measured against a deuterium lamp background correction system (over 60 times correction capability). Up to seven lamps can be preheated, enabling rapid element switching for cadmium, lead, zinc, and other heavy-metal analyses.
The instrument supports USB 3.0 interface for rapid data transmission and external PC control. Compatible with Windows XP and Windows 7 systems, it includes bilingual (Chinese/English) analytical software for quantitative and qualitative analysis, spectral correction, and GLP-compliant report output.
| Model | Specifications |
|---|---|
| T8001 | 190–900 nm range, Czerny–Turner optics, 3000 °C/s heating, USB 3.0 interface, ≤ 1 pg detection limit, 150-position autosampler |
The AELAB T8001 is ideal for environmental, food safety, pharmaceutical, and metallurgical laboratories. It quantifies trace metals such as Cd, Pb, Zn, Cu, Fe, and Ni in water, soil, biological, and industrial samples with superior sensitivity and repeatability.
Manufactured under ISO and CE guidelines, the T8001 ensures GLP compliance, traceable calibration accuracy, and strict AELAB quality control standards for laboratory and industrial use.
| Parameter | Specification |
|---|---|
| Wavelength Range | 190 nm – 900 nm |
| Grating Line | 1800 lines/mm |
| Wavelength Repeatability | < 0.05 nm |
| Static Baseline Stability | 0.003 Abs (static) |
| Monochromator Type | Czerny–Turner |
| Wavelength Accuracy | ± 0.2 nm |
| Resolution Ratio | Better than 0.3 nm |
| Deuterium Lamp Background Correction Ability | Over 60 times |
| Temperature Control Range of Graphite Furnace | Room temperature – 3000 °C |
| Heating Rate of Graphite Furnace | 3000 °C/s |
| Graphite Furnace Measurement of Cd Characteristic Quantity | ≤ 0.5 pg |
| Detection Limit of Cd in Graphite Furnace | ≤ 1 pg |
| Grating Flash Wavelength | 230 nm |
| Spectral Bandwidth | 0.1 / 0.2 / 0.4 / 0.7 / 1.4 nm – Five gear automatic switching |
| Precision of Cd Measurement in Graphite Furnace | ≤ 2 % |
| Power Supply | 220 V ± 22 V, 50 Hz ± 1 Hz, 5 kW (peak) |
The AELAB T8001 Graphite Furnace Atomic Absorption Spectrometer is a high-performance analytical instrument designed for the precise determination of trace and ultra-trace metal elements in a wide range of samples. By combining atomic absorption spectrometry with advanced graphite furnace technology, the instrument achieves extremely low detection limits and high analytical sensitivity, making it suitable for laboratories that require reliable elemental analysis.
Unlike conventional analytical systems that may struggle with very low concentration measurements, the T8001 utilizes a graphite furnace atomization process that significantly enhances detection capability. The instrument integrates the graphite furnace and atomic absorption system into a unified platform, reducing signal interference while improving measurement stability, accuracy, and repeatability for demanding laboratory applications.
The operating principle of the T8001 is based on atomic absorption spectroscopy. During analysis, a sample is introduced into a graphite tube where it undergoes a programmed heating sequence. As the temperature increases, the sample is dried, decomposed, and finally atomized. The free atoms generated within the graphite furnace absorb light at specific wavelengths corresponding to the target element.
The instrument measures the amount of absorbed light and converts this information into concentration values. Advanced optical components, wavelength selection systems, and background correction technology help eliminate unwanted interferences. This process enables highly accurate quantification of metallic elements even when present at extremely low concentrations.
The graphite furnace serves as the core analytical component of the T8001. It provides a controlled high-temperature environment capable of reaching temperatures suitable for atomizing trace elemental species. This approach offers significantly greater sensitivity than traditional flame-based atomic absorption methods.
The furnace incorporates temperature monitoring and safety protection systems that help maintain stable operating conditions. Automated heating programs ensure consistent sample treatment, reducing operator influence and improving analytical reproducibility.
The spectrometer utilizes a sophisticated optical design intended to maximize light utilization and improve measurement accuracy. High-quality optical components help focus and direct the analytical beam efficiently, allowing the instrument to detect subtle absorption signals from trace elements.
Enhanced wavelength selection and optical stability contribute to improved precision during long analytical runs. This is particularly important in laboratories that process large sample batches and require consistent analytical performance throughout the day.
The AELAB T8001 is equipped with an automated sample handling system that streamlines laboratory workflows. Automated sample introduction minimizes manual intervention, helping reduce human error and improving consistency between measurements.
For routine testing laboratories, this automation increases productivity by allowing multiple samples to be processed in sequence. The result is faster analytical throughput without compromising measurement quality.
The instrument is designed to measure trace concentrations of metallic and semi-metallic elements in liquid samples. It is particularly effective when laboratories need to detect contaminants or essential elements at very low concentration levels that would be difficult to quantify using less sensitive analytical techniques.
Because of its high sensitivity, the T8001 is widely used for monitoring environmental pollutants, evaluating water quality, analyzing food products, examining pharmaceutical materials, and supporting scientific research projects involving elemental composition studies.
One of the primary applications of the T8001 is the determination of toxic heavy metals. Laboratories can use the instrument to identify and quantify elements such as cadmium, lead, arsenic, and other potentially hazardous metals that may affect environmental and human health.
The graphite furnace technique provides the sensitivity required to meet strict regulatory requirements for heavy metal monitoring. This makes the instrument particularly valuable for compliance testing and environmental protection programs.
The system is also suitable for measuring essential trace elements in biological, agricultural, and industrial samples. Researchers often require highly accurate elemental data to evaluate nutrient levels, process efficiency, or material quality.
By delivering low detection limits and reliable repeatability, the T8001 supports advanced analytical investigations where precision and sensitivity are critical requirements.
The versatility of the instrument allows it to be used across numerous industries and research fields. Environmental laboratories employ the system for monitoring water, soil, and industrial discharge samples to ensure compliance with environmental regulations.
Food testing facilities use the instrument to verify product safety and identify trace contaminants. Pharmaceutical laboratories rely on accurate elemental analysis to support quality control and regulatory compliance, while academic institutions utilize the technology for scientific research and materials characterization.
Environmental agencies and testing centers require highly sensitive instrumentation to monitor pollutants at trace levels. The T8001 enables accurate determination of metal contaminants in drinking water, wastewater, and environmental samples.
Its low detection capability helps laboratories identify contamination before it reaches hazardous levels, supporting environmental protection and public health initiatives.
Food manufacturers and testing laboratories use elemental analysis to verify product safety and compliance with international standards. The presence of heavy metals in food products can pose significant health risks, making accurate testing essential.
The T8001 provides the sensitivity necessary to detect contaminants at concentrations well below regulatory limits, helping organizations maintain product quality and consumer confidence.
The instrument offers several important advantages, including high sensitivity, low detection limits, automated operation, and excellent analytical stability. These characteristics allow laboratories to generate reliable results while minimizing manual workload and operational complexity.
In addition, integrated system design, advanced background correction capabilities, automated sample handling, and sophisticated temperature control contribute to improved analytical performance. As a result, the AELAB T8001 Graphite Furnace Atomic Absorption Spectrometer represents a powerful solution for laboratories seeking accurate and dependable trace elemental analysis.
(0/10)