Overview
The Class II B2 Biological Safety Cabinet EB2 Series is designed to provide maximum protection for personnel, samples, and the environment in high-containment laboratory settings. It features a color touch screen for real-time data display and scheduled operation, along with a remote control for convenient, contact-free use.
For improved ergonomics and safety, a foot switch allows hands-free adjustment of the front window height, minimizing airflow disruption. The cabinet is equipped with a wind speed sensor and energy-efficient EC fan for stable performance.
Mobility and stability are ensured with Footmaster casters, while a stepper motor and manual handle offer dual control of the front window. Additional features include support blocks, an iron hook support rod for safe panel positioning, and a UV lamp emitting 253.7 nm for effective decontamination.
This unit is ideal for laboratories requiring strict biosafety measures, combining advanced technology with user-friendly design.
Features:
- 7 – inch touch color display screen: touch operation, real – time more clear and dynamic display of various values of the safety cabinet, and has the function of appointment timing.
- The power – on password can be set to prevent unrelated personnel from mis – operation.
- Automatically adjust the wind speed.
- With power – off memory function, the state before power – off will be restored after power – on, and there will be visual prompts and alarms.
- The integrated design of the operation area makes it easy to disassemble and clean.
- The working area is equipped with a wind speed sensor to detect the wind speed in real – time.
- It can be used manually or electrically, and the front window can be closed by pulling down the glass door when the power is off.
- The cabinet is separated from the base. The height of the adjustable base can be customized.
- Interlocking function: UV lamp and front window; UV lamp and fan; LED lamp; fan and front window.
- It has the function of appointment timing, which can automatically set the time of starting and shutting down the safety cabinet and the running time of ultraviolet lamps, fans and sockets.
- The front window closes the double trigger signal, so that the sterilization and disinfection function of the ultraviolet lamp is normally turned on.
- The negative pressure air duct is equipped with a foreign matter filtering structure to prevent foreign matter such as paper scraps from entering the fan system and affecting the normal operation of the product.
- The front window glass has a one – key lift function.
- The cabinet is designed with a 10° inclination angle, which is in line with ergonomic principles, has a larger viewing angle, is easy to operate and is more user – friendly.
✅ 🔬 How It Works?
The EB2 Series ensures 100% air exhaust with zero recirculation, offering maximum containment. Ambient air is drawn in through the front grille, creating a barrier between operator and sample. HEPA-filtered downflow protects samples, while contaminated air is pulled through ULPA filters before safe external venting. Advanced microprocessor controls adjust airflow in real time, supported by wind speed sensors, visual alarms, and scheduled operations to maintain biosafety integrity.
✅ 💡 Advantages
-
Ultimate Containment: 100% exhaust airflow system meets stringent biosafety standards
-
Smart Operation: Touchscreen control, remote access, and foot switch for seamless handling
-
Filter Safety: Filter life indicator and alarms for airflow deviation or high pressure
-
Ergonomic Design: 10° inclined front panel and customizable height ensure user comfort
-
Power Failure Recovery: Auto memory restores settings and alerts after outages
-
Timed Sterilization: Schedule UV, fan, and socket operations for hands-free control
-
Effortless Maintenance: One-key lift front window and detachable components streamline cleaning
✅ 🔍 Recommended Models by Use Case
-
EB2-3F: Ideal for small educational or clinical labs with limited space
-
EB2-4F: Balanced choice for university labs and public health research
-
EB2-5F: Suits pharmaceutical QC departments and core research facilities
-
EB2-6F: Best for high-throughput labs, biosafety level 3 zones, or shared research environments
✅ 🧪 Ideal For
-
Microbiology and virology labs
-
Pharmaceutical production QA/QC
-
Clinical diagnostics labs
-
Biosafety Level 2 and Level 3 facilities
-
Biotechnology R&D departments
-
University research and training centers