Ceramic-Coated Aluminum Hotplates & Stirrers HSHA / HHA / HSA Series

Ceramic-Coated Aluminum Hotplates & Stirrers HSHA / HHA / HSA Series

Model :HSHA-200~HSHA-300~HHA-200~HHA-300~HSA-200~HSA-300

  • Available Configurations: HSHA hotplate stirrers, HHA hotplates, and HSA magnetic stirrers in 200 and 300 models
  • Working Plate: Ceramic-coated aluminum; 7 in. (178 × 178 mm) or 10 in. (254 × 254 mm)
  • Heating Range: HSHA/HHA plate temperature 35–400°C; solution range 35.0–200.0°C with PT 1000
  • Magnetic Stirring: HSHA/HSA speeds of 150–1600 rpm or 150–1500 rpm, with up to 10 L or 20 L H2O depending on model
  • Safety & Protection: Hot warning and overheat detection on heating models, spill-proof framework structure, and IP 21 protection

Overview

Product Overview

The AELAB HSHA / HHA / HSA Series includes ceramic-coated aluminum laboratory hotplates, magnetic stirrers, and combined hotplate stirrers for heating and/or stirring solutions. The catalog identifies chemistry, biology, and other laboratory fields requiring temperature control and solution mixing as typical application areas.

Six models are available in three functional configurations. HSHA-200 and HSHA-300 combine heating with magnetic stirring, HHA-200 and HHA-300 provide laboratory heating, and HSA-200 and HSA-300 provide magnetic stirring. All six models use an LED display and a ceramic-coated aluminum working plate.

The 200 models use a 7-inch (178 × 178 mm) plate, while the 300 models use a 10-inch (254 × 254 mm) plate. HSHA and HHA heating models provide a plate temperature setting and heating range of 35–400°C. With the PT 1000 external temperature sensor, the specified solution heating range is 35.0–200.0°C.

Heating models provide 1°C plate-temperature setting resolution, 0.1°C solution-temperature setting resolution, and 1°C temperature stability. Heat control accuracy with the PT 1000 is specified as +/-0.5°C under the catalog test conditions of 500 ml H2O in a 600 ml beaker, a 30 mm stirring bar, 600 rpm, and 50°C.

HSHA and HSA stirring models provide a speed range of 150–1600 rpm on 200 models and 150–1500 rpm on 300 models. The specified maximum stirring quantity is 10 L H2O for 200 models and 20 L H2O for 300 models.

Key Features

  • Three Functional Configurations: HSHA models combine heating and magnetic stirring, HHA models provide heating, and HSA models provide magnetic stirring.
  • Ceramic-Coated Aluminum Plate: All six models use the same catalog-specified working plate material.
  • Two Plate Sizes: 200 models use a 7-inch (178 × 178 mm) plate, while 300 models use a 10-inch (254 × 254 mm) plate.
  • LED Display: LED display is standard across all catalog-listed models.
  • 35–400°C Plate Heating: HSHA and HHA models provide a temperature setting range and plate heating range of 35–400°C.
  • PT 1000 Solution Temperature Control: Heating models provide a 35.0–200.0°C solution heating range using the external PT 1000 temperature sensor.
  • Temperature Setting Resolution: Heating models provide 1°C plate-setting resolution and 0.1°C solution-setting resolution.
  • External Probe Calibration: HSHA and HHA models support calibration on the external probe.
  • Magnetic Stirring: HSHA/HSA 200 models operate from 150–1600 rpm with 25–60 mm stir bars; 300 models operate from 150–1500 rpm with 30–80 mm stir bars.
  • Heating Safety Functions: Heating models include hot warning, plate and medium overheat detection, and catalog-described over-temperature protection.
  • Hot-Surface Warning: The catalog specifies a hot warning light when plate temperature exceeds 50°C.
  • Spill-Proof Framework Structure: The catalog states that the framework is designed to prevent spilled water from entering the case.
  • Operating Environment: All models specify an ambient operating temperature of 5–40°C, 80% relative humidity, and IP 21 protection according to DIN EN 60529.

Applications

  • Chemistry Laboratories: Heating and/or stirring solutions for laboratory work requiring temperature control and mixing.
  • Biology Laboratories: Laboratory solution heating and mixing where controlled temperature or magnetic stirring is required.
  • Solution Heating: HSHA and HHA models provide controlled plate heating from 35°C to 400°C.
  • Magnetic Solution Stirring: HSHA and HSA models provide magnetic stirring at speeds up to 1600 rpm depending on model.
  • Simultaneous Heating and Stirring: HSHA models combine both functions in one laboratory instrument.

Available Models and Comparison

Model Function Plate Size Plate Heating Range Speed Range Max. Stirring Quantity (H2O)
HSHA-200 Heating + Magnetic Stirring 7 in. (178 × 178 mm) 35–400°C 150–1600 rpm 10 L
HSHA-300 Heating + Magnetic Stirring 10 in. (254 × 254 mm) 35–400°C 150–1500 rpm 20 L
HHA-200 Heating 7 in. (178 × 178 mm) 35–400°C – 10 L
HHA-300 Heating 10 in. (254 × 254 mm) 35–400°C – 20 L
HSA-200 Magnetic Stirring 7 in. (178 × 178 mm) – 150–1600 rpm 10 L
HSA-300 Magnetic Stirring 10 in. (254 × 254 mm) – 150–1500 rpm 20 L

Product Information

  • Brand: AELAB
  • Manufacturer: AELAB GUANGZHOU CO., LTD.
  • Product Type: Ceramic-Coated Aluminum Hotplates, Magnetic Stirrers and Hotplate Stirrers
  • Series: HSHA / HHA / HSA Series
  • Models: HSHA-200, HSHA-300, HHA-200, HHA-300, HSA-200, HSA-300
  • Core Functions: Laboratory solution heating, magnetic stirring, or combined heating and stirring depending on model
  • Catalog Applications: Chemistry, biology, and other laboratory fields requiring temperature control and solution mixing

FAQ

What models are available in the HSHA / HHA / HSA Series?

The series includes HSHA-200, HSHA-300, HHA-200, HHA-300, HSA-200, and HSA-300.

What is the difference between the HSHA, HHA and HSA models?

HSHA models combine heating and magnetic stirring, HHA models provide heating, and HSA models provide magnetic stirring.

What plate sizes are available?

The 200 models use a 7-inch (178 × 178 mm) plate, while the 300 models use a 10-inch (254 × 254 mm) plate.

What is the heating temperature range?

HSHA and HHA heating models provide a plate temperature setting and heating range of 35–400°C.

Can liquid temperature be controlled with an external sensor?

Yes. HSHA and HHA models use a PT 1000 external temperature sensor and provide a solution heating range of 35.0–200.0°C.

What is the specified heat control accuracy with the PT 1000?

The catalog specifies +/-0.5°C under test conditions of 500 ml H2O in a 600 ml beaker, a 30 mm stirring bar, 600 rpm, and 50°C.

What stirring speeds do the HSHA and HSA models provide?

HSHA-200 and HSA-200 operate from 150–1600 rpm. HSHA-300 and HSA-300 operate from 150–1500 rpm.

What is the maximum stirring quantity?

The catalog specifies 10 L H2O for 200 models and 20 L H2O for 300 models.

What safety features are specified for the heating models?

The catalog specifies over-temperature protection, hot warning when the plate temperature exceeds 50°C, plate and medium overheat detection, and a spill-proof framework structure.

Who manufactures the HSHA / HHA / HSA Series?

The products are supplied under the AELAB brand by AELAB GUANGZHOU CO., LTD.

Specifications

Model HSHA-200 HSHA-300 HHA-200 HHA-300 HSA-200 HSA-300
Display LED LED LED LED LED LED
Plate material Ceramic coated aluminum Ceramic coated aluminum Ceramic coated aluminum Ceramic coated aluminum Ceramic coated aluminum Ceramic coated aluminum
Plate dimensions (mm) 7" (178X178mm) 10" (254X254mm) 7" (178X178mm) 10" (254X254mm) 7" (178X178mm) 10" (254X254mm)
Hot warning yes yes yes yes - -
Temperature setting range 35-400°C 35-400°C 35-400°C 35-400°C - -
Heating range for plate 35-400°C 35-400°C 35-400°C 35-400°C - -
Heating range for solution 35.0-200.0°C 35.0-200.0°C 35.0-200.0°C 35.0-200.0°C - -
External temperature sensor PT 1000 PT 1000 PT 1000 PT 1000 - -
Heating setting resolution of plate 1 °C 1 °C 1 °C 1 °C - -
Heating setting resolution of solution 0.1 °C 0.1 °C 0.1 °C 0.1 °C - -
Temperature stability 1 °C 1 °C 1 °C 1 °C - -
Heat control accuracy with PT 1000 (500ml H2O in 600ml beaker, 30mm stirring bar, 600rpm, 50°C) +/-0.5 °C +/-0.5 °C +/-0.5 °C +/-0.5 °C - -
Capable calibration on external probe yes yes yes yes - -
Number of stirring positions 1 1 1 1 1 1
Stirring quantity max. per stirring position (H2O) 10L 20L 10L 20L 10L 20L
Speed range (rpm) 150-1600 150-1500 - - 150-1600 150-1500
Stir Bar Length Range(mm) 25-60 30-80 - - 25-60 30-80
Overheat warning in plate and medium detection (Error 1 and Error 2) yes yes yes yes - -
Dimensions (W x D x H) mm 192X293X100 292X422X110 192X293X100 292X422X110 192X293X100 292X422X110
Weight 3.5 Kg 7.0 Kg 3.5 Kg 7.0 Kg 3.0 Kg 6.0 Kg
Operation ambient temperature 5 - 40 °C 5 - 40 °C 5 - 40 °C 5 - 40 °C 5 - 40 °C 5 - 40 °C
Operation relative humidity 80% 80% 80% 80% 80% 80%
Protection class according to DIN EN 60529 IP 21 IP 21 IP 21 IP 21 IP 21 IP 21
Voltage 110-130V/ 200-240V 110-130V/ 200-240V 110-130V/ 200-240V 110-130V/ 200-240V 110-130V/ 200-240V 110-130V/ 200-240V
Frequency 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz
Power 900 W 1600 W 900 W 1600 W 900 W 1600 W

Request Quote: Ceramic-Coated Aluminum Hotplates & Stirrers HSHA / HHA / HSA Series

Request Quote: Ceramic-Coated Aluminum Hotplates & Stirrers HSHA / HHA / HSA Series

(0/10)