Flame & Graphite Furnace Integrated Atomic Absorption Spectrometer T8001S

Flame & Graphite Furnace Integrated Atomic Absorption Spectrometer T8001S

Model :T8001S

The AELAB T8001S is a flame & graphite furnace integrated atomic absorption spectrometer for quantifying major, trace, and semi-metallic elements. It combines a Czerny–Turner monochromator, automatic wavelength control, and USB3.0 software for precise photometric measurement in environmental, industrial, and research laboratories.

Overview

Instrument Description

  • The AELAB T8001S Flame Graphite Furnace Integrated Atomic Absorption Spectrometer is used to determine the content of major, trace, and semi-metallic elements in various substances.
  • The machine adopts a PC and Chinese interface operation software, making the instrument operation simple and intuitive.
  • By applying advanced electronic circuit systems and USB3.0 communication control, the instrument achieves automatic adjustment of wavelength scanning, peak finding and positioning, spectral pass band width, rotating element lamp holder, atomizer height and position, gas flow rate, lamp current, and negative high voltage of photomultiplier tubes.
  • The instrument stores reference conditions for analysis of all measured elements in various analysis methods. Users can modify operating conditions as needed, and save operating conditions, working curves, and test results to disk for recall and processing.

 

Flame System

  • Pure Titanium atomization chamber: effectively prevents acid gas corrosion and has a longer service life.
  • Acetylene flow control with Mass Flow Controller: continuously adjustable with dynamic monitoring for easy, safe, and reliable operation.
  • Efficient glass atomizer: a dedicated high-efficiency glass atomizer for high atomization efficiency and convenient maintenance and replacement.
  • Security measures: (1) acetylene leakage monitoring; (2) acetylene pressure monitoring; (3) air pressure monitoring; (4) combustion head status monitoring; (5) flame status monitoring; (6) water seal status monitoring.

 

Graphite Furnace System

  • Integration: graphite furnace power supply and atomic absorption host in one instrument to shorten cable length, reduce electromagnetic interference, and improve heating efficiency of the graphite tube.
  • High temperature control accuracy & fast heating: high-power transformers, micro-resistance cables, and light-controlled heating, combined with software and hardware temperature correction; high-temperature section control accuracy up to ±1%.
  • Safety measures: (1) cooling water flow monitoring; (2) graphite tube temperature alarm; (3) carrier gas pressure alarm; (4) graphite furnace temperature alarm.
  • Automatic carrier gas flow: internal and external gases of the graphite furnace are computer-controlled according to the software heating process.
  • 150-bit rotary graphite furnace autosampler: polar coordinate turntable autosampler shared for flame and graphite furnace; high positioning accuracy, stable operation, convenient use and maintenance.

 

⚙️ Design & Construction — AELAB T8001S Atomic Absorption Spectrometer

The AELAB T8001S employs a Czerny–Turner monochromator for stable dispersion and a multi-slot element lamp turret with automatic rotation. A Pure Titanium atomization chamber resists acid gases; a high-efficiency glass atomizer ensures consistent aerosol formation. The integrated chassis houses the graphite furnace power supply and spectrometer to minimize EMI, while USB3.0 connectivity links the control software for GLP data handling.

 

🔬 Working Principle / Testing Method

The AELAB T8001S atomic absorption spectrometer measures elemental concentration by atomizing samples in either an air–acetylene flame or an electrothermal graphite furnace. Hollow cathode lamp radiation passes through the atom cloud; absorbance at element-specific wavelengths is measured with automatic wavelength scanning and peak positioning. Quantification uses calibration curves with stored reference conditions, supporting routine photometry and trace analysis under GLP.

 

💡 Key Advantages

  • Wide spectral coverage 190–900 nm with ±0.2 nm accuracy for multi-element analysis.
  • Switchable spectral bandwidth 0.1/0.2/0.4/0.7/1.4 nm to optimize sensitivity and linearity.
  • Flame mode detection limit <0.008 μg/mL and 0.003 Abs static stability for routine low-level quantitation.
  • Graphite furnace heating up to 3000 °C at 3000 °C/s for high-sensitivity electrothermal AAS.
  • Cd precision to ≤2% (auto) / ≤5% (manual); characteristic mass ≤0.5 pg for trace performance.
  • Built-in safety: multi-channel pressure, leakage, flame, water-seal, and temperature monitoring for safe operation.
  • USB3.0 software with automatic wavelength/peak control and method storage speeds workflows.

 

🔗 Connectivity & Integration

The AELAB T8001S connects via USB3.0 for instrument control, data acquisition, method storage, and GLP exports. The system records operating conditions, working curves, and test results for recall, audit, and reporting within laboratory LIMS workflows.

 

🧠 Model Insight — T8001S Variant Overview

Model Comparison – AELAB T8001S Atomic Absorption Spectrometer
Model Atomization Modes Wavelength Range Accuracy Spectral Bandwidth Graphite Furnace Range Power
T8001S Flame + Graphite Furnace (integrated) 190–900 nm ±0.2 nm; repeatability <0.05 nm 0.1/0.2/0.4/0.7/1.4 nm Room temperature–3000 °C; 3000 °C/s 220 V, 50 Hz, 5 kW (peak)

 

🧪 Testing Applications

The AELAB T8001S atomic absorption spectrometer supports elemental testing in environmental waters, soil and sludge digests, food and feed, pharmaceuticals, petrochemicals, metallurgy, and academic research. Use flame AAS for mid-μg/L to mg/L levels and the graphite furnace for pg–ng sensitivity in trace metals such as Cd, Pb, Cu, Zn, and Ni.

 

Compliance & Quality Assurance

The AELAB T8001S is engineered for ISO/CE/GLP workflows. Automated wavelength control, method storage, and full monitoring of gases, flame, water-seal, and furnace temperature support audit trails. Calibration is traceable via stored working curves and reference conditions for reproducible analysis.

Specifications

Technical Specifications – AELAB T8001S
Complete machine
Monochromator type Czerny-Turner
Wavelength range 190 nm~900 nm
Wavelength accuracy ±0.2 nm
Wavelength repeatability <0.05 nm
Spectral bandwidth 0.1/0.2/0.4/0.7/1.4 nm Automatic switching of five gears
Flame system
Precision <0.8% (flame method for copper measurement)
Static stability 0.003 Abs (static)
Detection limit <0.008 ug/mL
Dynamic stability <0.05 nm
Characteristic concentration <0.025 μg/ml/1% (Flame method for measuring copper)
Graphite furnace system
Temperature control range of graphite furnace Room temperature–3000 ℃
Heating rate of graphite furnace 3000 ℃/s
Precision of cadmium (Cd) measurement in graphite furnace ≤2% (Automatic injection mode)
Precision of cadmium (Cd) measurement in graphite furnace ≤5% (Manual injection mode)
Detection limit of cadmium (Cd) in graphite furnace ≤lpg (Automatic injection mode)
Detection limit of cadmium (Cd) in graphite furnace ≤2 pg (Manual injection mode)
Graphite furnace measurement of cadmium (Cd) characteristic quantity ≤0.5 pg
Power supply 220 V ± 22 V, 50 Hz ± 1 Hz, 5 kW (peak value)

application

What Is the AELAB T8001S?

The AELAB T8001S is an integrated Flame and Graphite Furnace Atomic Absorption Spectrometer. It is designed for elemental analysis, especially when a laboratory needs to measure metallic and semi-metallic elements in different types of samples.

This model combines two atomization techniques in one instrument: flame atomization and graphite furnace atomization. This makes it suitable for both routine concentration testing and trace-level analysis where very small amounts of elements must be detected accurately.

What Is It Used For?

The main application of the AELAB T8001S is to determine the concentration of elements in liquids, digested solids, environmental samples, food samples, industrial materials, chemical solutions, and research samples.

It is commonly used when laboratories need to check whether a sample contains specific metals such as copper, cadmium, lead, zinc, iron, nickel, chromium, manganese, and other analytes depending on the selected hollow cathode lamp and analytical method.

What Does It Test?

This instrument tests the elemental content of a sample. In practical terms, it helps the user find out how much of a specific metal or semi-metal is present in a prepared solution.

The AELAB T8001S is suitable for major elements, trace elements, and semi-metallic elements. The graphite furnace system is especially useful for very low concentration testing, while the flame system is typically used for faster routine measurements at higher concentration levels.

How Does It Work?

The instrument works based on atomic absorption spectroscopy. A sample is converted into free atoms, and a light beam with a specific wavelength passes through those atoms. The target element absorbs part of that light, and the instrument calculates the element concentration from the amount of absorption.

In flame mode, the sample is sprayed into a flame using an atomizer, where it is converted into atoms for measurement. In graphite furnace mode, a very small sample volume is placed inside a graphite tube and heated through programmed temperature stages, allowing much higher sensitivity for trace analysis.

Flame and Graphite Furnace Integration

One of the important advantages of this model is its integrated design. The flame system and graphite furnace system are built into the same instrument, so the user does not need to replace major hardware parts when switching between methods.

The software-controlled switching helps reduce manual operation errors and improves workflow efficiency. This is useful for laboratories that need both routine flame analysis and high-sensitivity graphite furnace analysis in one system.

Key Features of the AELAB T8001S

Automatic Software Control

The AELAB T8001S is controlled by PC software, which manages important operating parameters such as wavelength scanning, peak search, lamp selection, atomizer position, gas flow, lamp current, and detector voltage.

This level of automation helps simplify operation and improves repeatability. It also allows users to save methods, calibration curves, operating conditions, and test results for future use.

Eight-Lamp Turret

The instrument includes an eight-element lamp turret. This allows one lamp to be used while other lamps can be preheated, reducing waiting time during multi-element analysis.

For laboratories that test several elements in one working day, this feature can make operation faster and more convenient, especially compared with instruments that require frequent manual lamp replacement.

Background Correction

The T8001S includes background correction using deuterium lamp and self-absorption correction modes. This is important because real samples often contain matrix components that can interfere with accurate readings.

Background correction helps separate the true absorption signal of the target element from unwanted background absorption. This improves result reliability, especially in complex samples.

Graphite Furnace Sensitivity

The graphite furnace system provides high sensitivity for trace-level analysis. It is designed for precise temperature control and rapid heating, which are essential for accurate atomization of very small sample volumes.

This makes the instrument suitable for applications where the element concentration is extremely low and flame analysis may not be sensitive enough.

Safety Monitoring

The flame system includes safety monitoring for acetylene leakage, acetylene pressure, air pressure, burner head status, flame status, and water seal status.

The graphite furnace system also includes safety monitoring for cooling water flow, carrier gas pressure, graphite tube temperature, and furnace temperature. These protections help make the analysis process safer and more stable.

Where Is It Used?

The AELAB T8001S can be used in environmental testing laboratories, food safety laboratories, water quality laboratories, industrial quality control departments, universities, research centers, and chemical analysis laboratories.

It is especially useful in facilities that need to measure metals in drinking water, wastewater, soil extracts, food digests, biological samples, raw materials, finished products, and laboratory-prepared solutions.

Why Choose This Model?

The main reason to choose the AELAB T8001S is its combination of flame and graphite furnace capability in a single instrument. This gives the laboratory more flexibility without requiring two separate systems.

Its automated functions, integrated optical design, background correction system, automatic sampler compatibility, and safety controls make it suitable for laboratories that need reliable elemental analysis with both routine and trace-level testing options.

Conclusion

The AELAB T8001S Flame and Graphite Furnace Integrated Atomic Absorption Spectrometer is a laboratory instrument for measuring metallic and semi-metallic elements in different sample types.

With both flame and graphite furnace analysis in one unit, it supports fast routine testing as well as high-sensitivity trace analysis. This makes it a practical choice for environmental, industrial, academic, and quality control laboratories.

Request Quote: Flame & Graphite Furnace Integrated Atomic Absorption Spectrometer T8001S

Frequently Asked Questions

1What elements can the AELAB T8001S measure?
It measures major, trace, and semi-metallic elements such as Cu, Zn, Pb, Cd, Fe, and Mn.
2What is the maximum graphite furnace temperature?
The furnace operates up to 3000 °C with a heating rate of 3000 °C/s.
3Does the T8001S support automatic wavelength adjustment?
Yes, it provides automatic wavelength scanning, peak positioning, and spectral bandwidth switching.
4Can the instrument export data?
Yes, it supports USB 3.0 data export and full PC software integration.
5What safety features are included?
The system monitors acetylene leakage, air pressure, combustion head, flame status, and cooling water flow.

Request Quote: Flame & Graphite Furnace Integrated Atomic Absorption Spectrometer T8001S

(0/10)