Overview
Product Overview
The AELAB F93 is a Fluorescence Spectrophotometer designed for sensitive and selective fluorescence analysis, including trace-analysis applications in medical science, pharmaceuticals, biochemistry, food analysis, pollution analysis, and organic and inorganic chemistry.
The F93 uses an LED excitation source with a standard central wavelength of 365nm. Its emission monochromator adopts a 1200-line diffraction grating together with a large optical aperture and non-spherical reflecting mirrors to provide high sensitivity.
The instrument provides an emission wavelength range of 360~650nm, 12nm bandwidth, wavelength accuracy of ±2nm and wavelength repeatability of ≤1nm. Automatic zero adjustment, automatic background subtraction and eight-stage sensitivity adjustment support routine fluorescence measurement.
Key Features
- 365nm LED Excitation: The standard F93 configuration uses an LED with a central wavelength of 365nm.
- 1200-Line Diffraction Grating: The emission monochromator uses a 1200-line diffraction grating.
- High-Sensitivity Optical Design: A large aperture and non-spherical reflecting mirrors are used to increase sensitivity.
- Cold-Light LED Source: The catalog describes the LED as providing longevity, lower background and reliable operation while helping prevent thermo-pollution.
- Replaceable LED: The excitation LED can be replaced to support other catalog-listed wavelength choices.
- Automatic Zero Adjustment: Automatic zero adjustment simplifies measurement operation.
- Automatic Background Subtraction: Background subtraction is performed automatically.
- Eight-Stage Sensitivity Adjustment: Provides eight sensitivity levels for different fluorescence signals.
- Real-Time Reading: Displays fluorescence readings in real time.
- Wide Dynamic Range: The catalog specifies an extra-wide dynamic range for fluorescence readings and measurement of minute sample changes.
- RS-232C Interface: Provides an RS232 serial port for communication.
- Optional PC Data Processing: With the optional Data Processing Software Package, data can be stored, transmitted and used to draw up a standard operating curve.
Applications
- Medical Science and Clinical Analysis: Clinical analysis of biological specimens.
- Pharmaceutical Science and Pharmacology: Analysis of natural pharmaceutical products, pharmaceutical quality control and research of pharmaceutical metabolites.
- Biochemistry: Analysis of minute quantities of substances in biological bodies.
- Food Industry: Analysis of minute quantities of constituents in food.
- Pollution Analysis: Atmospheric pollution analysis, environmental testing and food contamination analysis.
- Organic and Inorganic Chemistry: Trace analysis of substances that cannot be determined by absorption spectrophotometry.
- Education and Laboratories: The catalog specifically describes the F93 as suitable for Education & Lab use.
Fluorescence Measurement System
- Light Source: LED
- Standard F93 Excitation Wavelength: 365nm
- Emission Wavelength: 360~650nm (C-T diffraction grating)
- Bandwidth: 12nm
- Wavelength Accuracy: ±2nm
- Wavelength Repeatability: ≤1nm
- Sensitivity: 1×10-9 g/ml under the test condition stated in the catalog
- Linearity Deviation: ≤±3.0%
Replaceable LED Light Source Options
The standard F93 specification lists a 365nm LED. The catalog separately lists the following LED light-source options:
- 255nm
- 265nm
- 280nm
- 310nm
- 325nm
- 335nm
- 345nm
- 350nm
- One selected wavelength from 365—525nm
Standard Parts
- Main instrument — 1 set
- Power cord — 1 pc
- Instruction manual — 1 copy
- Product quality certificate — 1 copy
- Fuse (1A) — 2 pcs
- Fuse (5A) — 2 pcs
- Glass fluorescence cuvette 10mm — 1 pair
- Packing list — 1 copy
Optional Accessories and Spare Parts
- Fuses (1A/5A)
- LED light source
- Glass fluorescence cuvette 10mm
- Data processing software package (pack, for PC)
- RS-232C serial port cable
Product Information
- Brand: AELAB
- Manufacturer: AELAB GUANGZHOU CO., LTD.
- Product Type: Fluorescence Spectrophotometer
- Model: F93
- Product Standard: Enterprise Standard Q/SEEK3
- Display Mode: 4 digits LED
- Standard Excitation Wavelength: 365nm
- Emission Wavelength: 360~650nm
FAQ
What is the F93 Fluorescence Spectrophotometer used for?
The F93 is used for fluorescence analysis and trace-analysis applications. The catalog identifies medical and clinical analysis, pharmaceutical science, biochemistry, food analysis, pollution analysis, and organic and inorganic chemistry.
What excitation wavelength does the standard F93 use?
The standard F93 specification uses an LED with a central wavelength of 365nm.
What is the emission wavelength range?
The specified emission wavelength range is 360~650nm using a C-T diffraction grating.
What are the wavelength accuracy and repeatability?
Wavelength accuracy is ±2nm and wavelength repeatability is ≤1nm.
What sensitivity is specified?
The catalog specifies 1×10-9 g/ml under its stated sulfuric-acid quinine standard condition at 12nm bandwidth.
Can the LED excitation wavelength be changed?
Yes. The catalog states that the LED can be replaced and lists 255, 265, 280, 310, 325, 335, 345 and 350nm options, as well as one selected wavelength from 365—525nm.
Does the F93 support PC data processing?
Yes, through the RS232 serial interface when used with the optional Data Processing Software Package. The catalog states that this setup supports data storage, transmission and preparation of a standard operating curve.
Is the PC data-processing software included as standard?
No. The Data Processing Software Package and RS-232C serial port cable are listed under optional accessories and spare parts.